| Parameter | Unit | Value |
|---|---|---|
| Display | - | 6-digit LED (net weight) + TFT LCD (parameters, gross weight, peak, unit) |
| Power Supply | V / Hz | DC 10-28V / AC 85-265V (100-240V, 50/60Hz) |
| Load Cell Capacity | Ω | Up to 8 × 350Ω load cells |
| Signal Range | mV/V | 0.5 - 3.0 |
| Excitation Voltage | V | 5 |
| Sampling Rate | Hz | 10 / 40 / 640 / 1280 (Adjustable) |
| Internal Resolution | - | 1/1,000,000 |
| Display Resolution | - | 1/100,000 |
| Nonlinearity | % F.S | 0.005 |
| Max Power Consumption | W | 5 |
| Operating Temperature | °C | -25 ~ +45 |
| Relative Humidity | % RH | <85 |
| Weight | g | Approx. 300 |
| Dimensions | mm | 96 × 48 × 110 |
| Panel Cutout | mm | 92 × 46 |
| Output Options | - | Analog output, RS485, 3 relay alarm outputs |
Product details
WEIGHING / PANEL INSTRUMENT
接入称重传感器信号,在控制面板上清晰呈现称重读数。
6 DIGIT
六位LED净重读数
5 V
称重传感器激励
92 × 46 mm
矩形面板开孔
产品概述
这款面板安装式称重显示控制仪表用于配套称重传感器,接收0.5–3.0 mV/V信号,通过六位LED主显示呈现净重读数。仪表提供5 V传感器激励;资料标注最多可带8只350 Ω称重传感器,表示带载能力,不表示独立通道数量。辅助显示窗用于参数、毛重、峰值和单位等内容,具体界面以所购实物为准。
核心特点
六位净重显示
主显示采用六位LED净重读数,并设辅助显示窗。参数资料将辅助显示内容列为参数、毛重、峰值和单位;适合在控制面板上查看称重信息。辅助显示的具体界面以所选实物为准。
称重传感器输入
信号范围0.5–3.0 mV/V,传感器激励电压5 V,资料标注带载能力最多8只350 Ω称重传感器。该数量表示传感器带载能力,不代表8个独立测量通道;选型时应匹配传感器电气参数。
四档采样设置
采样速率可选10、40、640或1280 Hz,便于按称重系统需求选择采样设置。内部分辨率为1/1,000,000,显示分辨率为1/100,000;这些指标不等同于测量精度或通讯刷新速度。
按配置选择输出
资料列出模拟量输出、RS485以及三路继电器报警输出选项,并标出外置清零输入端子。所需接口须按实际配置选购,不能默认所有输出均随附;模拟量规格、通讯协议和继电器触点额定值需在配套前确认。
面板安装与配套核对
外形96×48×110 mm,面板开孔92×46 mm。选购前核对柜体空间、供电铭牌及接线定义,确认传感器、线缆与安装配件的供货范围,便于完成系统配套。
工作方式与应用
称重传感器的信号接入S+、S−,激励连接E+、E−,称重读数由主显示窗呈现。按所选配置使用输出接口连接后续配套设备。配套前应核对传感器电气参数与实装接口。
适用于配套称重传感器的面板读数、控制柜称重显示等场景。输出配置应根据实际系统需要选择。
配置与选型
| 选型项目 | 需核对条件 |
|---|---|
| 供电选择 | 购买前确认所选仪表电源类型及实物铭牌,不将AC与DC标注理解成同一台机器可任意接入。 |
| 模拟量输出 | 配置选项;需确认电压/电流类型、信号范围及负载要求。 |
| RS485 | 配置选项;需确认通讯协议和通讯设置。 |
| 三路继电器报警 | 配置选项;需确认实装输出、触点定义和额定值。 |
尺寸与面板安装
开孔与安装前核对图纸基准、开孔公差、面板厚度及柜后接线余量。尺寸单位均为毫米。
接线参考
以下端子表用于选型核对。接线前核对实物及供电铭牌,尤其是19、20号电源端。实际可用接口取决于所购配置。
| 端子号 | 图示标识 | 定义 |
|---|---|---|
| 1 | A+ | RS485 A+ |
| 2 | B− | RS485 B− |
| 3 | DI− | 外置清零负端;电气类型待确认 |
| 4 | DI+ | 外置清零正端;电气类型待确认 |
| 5 | E+ | 传感器激励正端 |
| 6 | E− | 传感器激励负端 |
| 7 | S− | 传感器信号负端 |
| 8 | S+ | 传感器信号正端 |
| 9 | AO− | 模拟量变送输出负端;规格待确认 |
| 10 | AO+ | 模拟量变送输出正端;规格待确认 |
| 11–12 | OUT3 | 第三路继电器输出;常开/常闭及额定值待确认 |
| 13–15 | OUT2 | 第二路继电器输出;公共端及常开/常闭待确认 |
| 16–18 | OUT1 | 第一路继电器输出;公共端及常开/常闭待确认 |
| 19 | DC− / L | 图示直流负端或交流L;须先确认供电版本 |
| 20 | DC+ / N | 图示直流正端或交流N;须先确认供电版本 |
连接前确认DI输入、模拟量输出和继电器触点的电气条件;RS485接口名称本身不代表某个特定通讯协议。
产品展示与配套范围
照片展示仪表本体、显示窗、按键和后部接线端子。购买时请确认实际供货清单;称重传感器、电源设备、线缆及固定配件是否随附,以实际订单为准。
常见选型问题
最多八只传感器是否就是八个独立通道?
不是。此项是最多8只350 Ω称重传感器的带载能力,不代表独立测量通道数量。
所有输出都包含吗?
需按实际销售配置选购,确认模拟量、RS485及继电器输出是否实装。
1280 Hz是否代表通讯刷新速度?
不是。它是四档采样速率之一,资料没有给出通讯刷新速度。
安装前主要核对什么?
核对供电铭牌、传感器参数、端子定义、所需输出、面板开孔与实际供货清单。
| 端子号 | 图示标识 | 中文定义 | English definition |
|---|---|---|---|
| 1 | A+ | RS485 A+ | RS485 A+ |
| 2 | B− | RS485 B− | RS485 B− |
| 3 | DI− | 外置清零负端;电气类型待确认 | External zero negative; verify electrical type |
| 4 | DI+ | 外置清零正端;电气类型待确认 | External zero positive; verify electrical type |
| 5 | E+ | 传感器激励正端 | Load cell excitation positive |
| 6 | E− | 传感器激励负端 | Load cell excitation negative |
| 7 | S− | 传感器信号负端 | Load cell signal negative |
| 8 | S+ | 传感器信号正端 | Load cell signal positive |
| 9 | AO− | 模拟量变送输出负端;规格待确认 | Analog output negative; confirm signal specification |
| 10 | AO+ | 模拟量变送输出正端;规格待确认 | Analog output positive; confirm signal specification |
| 11–12 | OUT3 | 第三路继电器输出;常开/常闭及额定值待确认 | Relay output 3; verify contact type and rating |
| 13–15 | OUT2 | 第二路继电器输出;公共端及常开/常闭待确认 | Relay output 2; verify common and contact assignments |
| 16–18 | OUT1 | 第一路继电器输出;公共端及常开/常闭待确认 | Relay output 1; verify common and contact assignments |
| 19 | DC− / L | 图示直流负端或交流L;须先确认供电版本 | Diagram: DC negative or AC L; identify supply version first |
| 20 | DC+ / N | 图示直流正端或交流N;须先确认供电版本 | Diagram: DC positive or AC N; identify supply version first |
This six digit weighing indicator reads load cell signals and displays net weight on the main readout. Its housing fits a control panel, with 5V sensor excitation and terminals for external zero input. Check the load cell specifications, power supply version and required output configuration when selecting it for a weighing system.
这款六位称重显示控制仪表用于接收称重传感器信号,通过主显示窗呈现净重读数,适合嵌入控制柜面板。仪表提供五伏传感器激励,并设有外置清零端子。选购时需核对传感器参数、供电版本及所需输出配置,便于配套称重系统使用。
The indicator has a six digit main readout, an auxiliary display and rear terminals for sensor and output connections. Its load cell input range is 0.5-3.0 mV/V, with four sampling rate settings. The front measures 96 by 48 mm and the panel cutout is 92 by 46 mm, providing defined dimensions for checking the installation space.
仪表采用六位数字主显示窗和辅助显示窗,背部设有传感器及输出接线端子。传感器信号范围为零点五至三毫伏每伏,采样速率提供四档选择。面框宽九十六毫米、高四十八毫米,面板开孔为九十二乘四十六毫米,便于核对安装位置与配套条件。
For weighing systems that need a weight readout on a control cabinet, this indicator turns load cell signals into a panel display. Analog, RS485 and three relay alarm outputs are options to confirm for the selected unit. Check the supply nameplate, sensor wiring and panel cutout, and confirm whether sensors and cables must be supplied separately.
面向需要在控制柜上查看称重数值的配套系统,这款仪表将传感器信号转为面板读数。模拟量、串行通讯及三路继电器报警属于可选输出,应按实际配置选购。安装前核对供电铭牌、传感器接线和柜体开孔,并确认配套传感器及线缆是否另需准备。
Specifications
| Parameter | Unit | Value |
|---|---|---|
| Display | - | 6-digit LED (net weight) + TFT LCD (parameters, gross weight, peak, unit) |
| Power Supply | V / Hz | DC 10-28V / AC 85-265V (100-240V, 50/60Hz) |
| Load Cell Capacity | Ω | Up to 8 × 350Ω load cells |
| Signal Range | mV/V | 0.5 - 3.0 |
| Excitation Voltage | V | 5 |
| Sampling Rate | Hz | 10 / 40 / 640 / 1280 (Adjustable) |
| Internal Resolution | - | 1/1,000,000 |
| Display Resolution | - | 1/100,000 |
| Nonlinearity | % F.S | 0.005 |
| Max Power Consumption | W | 5 |
| Operating Temperature | °C | -25 ~ +45 |
| Relative Humidity | % RH | <85 |
| Weight | g | Approx. 300 |
| Dimensions | mm | 96 × 48 × 110 |
| Panel Cutout | mm | 92 × 46 |
| Output Options | - | Analog output, RS485, 3 relay alarm outputs |