PRODUCT MEDIA

产品影像

01 / 24
RS485称重变送器 · 1 1688 2店主图_1路 (1).jpg

主图 01

变送器

RS485称重变送器

参数名称单位参数值
电源V DC7 – 28
功耗W< 1
工作电流mA取决于传感器负载,最大 500
工作温度°C-40 ~ 85
湿度% RH0–95(无冷凝)
防护等级-IP65
支持传感器-惠斯通电桥式应变称重传感器
激励电压V DC5 ± 3%
传感器驱动能力Ω最多 8 × 350
输入信号范围mV0 – ± 30
分辨率-1/500,000
采样率Hz10, 40, 640, 1280
通讯接口-RS485、Modbus RTU
波特率-2400 – 500000
从机地址-DIP 0–15;软件 1–255;广播 254
模块重量g≈ 250

商品详情

INDUSTRIAL WEIGHING

惠斯通电桥信号接入 · Modbus RTU通讯

01_main.jpg

产品概述

这款RS485称重变送器用于惠斯通电桥式应变称重传感器的信号采集与数字通讯。传感器电桥信号经变送器处理后,通过RS485接口以Modbus RTU协议与主站交换数据,可用于具备相应接口及协议处理能力的PLC或工控机称重采集系统。变送器提供5 V DC ±3%激励,并支持10点分段校准。选型应核对传感器输出信号、阻抗、数量、线制以及主站通讯设置;最多驱动8只350 Ω传感器的规格不代表8个独立测量通道。主体宽100 mm,外壳高69 mm、深48.5 mm,含安装耳总宽131 mm,电缆接头的额外伸出需预留空间。安装与调试需要匹配的传感器、直流电源及主站设备,接线前应核对实物端子标识。订购前请确认型号、独立通道数、供电范围、输入信号范围及供货内容。

核心特点

电桥式信号接入

用于惠斯通电桥式应变称重传感器的信号采集。将传感器接入数字称重系统前,请核对输出信号、阻抗与激励要求。

RS485与Modbus RTU

通过RS485接口按Modbus RTU协议与PLC或工控机主站通讯,适合需要数字称重信号接入的系统;主站须具备对应接口、配置及协议处理能力。

5V激励与驱动能力

激励电压为5 V DC ±3%,驱动能力最多8只350 Ω传感器。驱动负载数量不代表独立测量通道数,选型时请确认具体通道配置。

采样与分段校准

采样率列有10、40、640、1280 Hz,支持10点分段校准。采样率与通讯刷新速度是不同指标,实际配置及更新时间请在系统集成前确认。

尺寸与安装规划

含安装耳总宽131 mm,设4个φ6 mm安装孔,孔中心横距112.5 mm、纵距42 mm,便于预先核对安装位置。订购前请确认供电范围、输入范围及供货内容。

工作方式与应用

电桥式称重传感器信号 → 变送器处理 → RS485 Modbus RTU主站。适用于PLC或工控机称重信号采集系统,传感器和主站须按电气接口与协议要求匹配。

05_views.jpg
02_specs.jpg

规格与选型

本页展示一种外形规格,通讯接口为RS485,协议为Modbus RTU。请根据传感器输出、阻抗、数量、线制和主站通讯设置选型。正式型号、独立输入通道数、供电范围及输入信号范围请在订购前确认。

尺寸与安装

上述数值用于安装位置核对。电缆接头另有伸出,请预留走线空间并确认整体安装包络尺寸。

04_dimensions.jpg

接线说明

端子组标识
电源电源+、电源−
通讯RS485A、RS485B、屏蔽线
传感器激励+、激励−、信号+、信号−、屏蔽

四线与六线传感器均有接法示意;六线SEN端的具体连接方式需确认,不应当作独立远端补偿功能承诺。接线前请断电,核对实物端子标识、极性及A/B,并使用确认后的接线图。

03_wiring.jpg

结构与供货内容

图片可见外壳、盖板、安装耳、两只电缆接头和内部接线端子。图示结构不构成包装清单。配套传感器、电源、PLC/工控机、线缆及安装附件是否包含在供货中,请在订购前核对。

常见问题

这是称重传感器吗?

这是与电桥式应变称重传感器配套的信号变送器。

最多驱动8只传感器就是8个通道吗?

不是。驱动负载能力与独立测量通道数不同,具体通道数需按订购型号确认。

分辨率等于精度吗?

不等同。1/500,000是分辨率,不应当作整体称重精度。

采样率等于通讯刷新速度吗?

两者不同,实际通讯更新时间需结合配置确认。

2 1688 2店详情页_2 1路_01_主图.jpg
2 1688 2店详情页_2_02_六大优势.jpg
2 1688 2店详情页_1路_03_技术参数.jpg
2 1688 2店详情页_2 1路_04_接线定义.jpg
2 1688 2店详情页_2 1路_05_安装尺寸.jpg
2 1688 2店详情页_2_04_接线定义.jpg
2 1688 2店详情页_2 1路_06_产品展示.jpg

产品介绍:中文

本产品为RS485称重变送器,用于惠斯通电桥式应变称重传感器的信号采集。传感器的电桥信号经变送器处理后,通过RS485接口以Modbus RTU协议与主站交换数据,可用于具备相应接口及协议处理能力的PLC或工控机称重采集系统。

变送器提供5 V DC ±3%激励,驱动能力最多8只350 Ω传感器,支持10点分段校准。选型时应核对传感器输出信号、阻抗、数量、线制及主站通讯设置;驱动数量不能作为独立测量通道数的依据。10、40、640、1280 Hz为采样率信息,实际通讯刷新速度需结合配置另行确认。

主体宽100 mm,外壳高69 mm、深48.5 mm,含安装耳总宽131 mm。安装孔为4个直径6 mm孔,孔中心横距112.5 mm、纵距42 mm;电缆接头额外伸出需预留空间。系统集成需要匹配的传感器、直流电源及主站,接线前请核对实物端子定义、供电极性及传感器线制。订购前请确认具体型号、独立通道数、供电适用范围、输入信号范围及供货内容;图示中的系统设备是否随附需单独核对。

Product description: English

This RS485 weight transmitter acquires signals from Wheatstone bridge strain gauge load cells and sends data to a host over RS485 using Modbus RTU. It is intended for integration into a weighing acquisition system with a PLC or industrial computer that can handle the required interface and protocol.

The unit provides 5 V DC ±3% excitation and supports 10-point segment calibration. Its drive capacity is listed as up to eight 350-ohm load cells; this is an electrical load rating, not a count of independent measurement channels. Select against the load cell output, impedance, quantity and wiring arrangement, together with the host communication settings. Sampling rates of 10, 40, 640 and 1280 Hz are separate from the communication update rate, which must be confirmed for the required configuration.

The main body is 100 mm wide, with a housing height of 69 mm and depth of 48.5 mm. Overall width including mounting flanges is 131 mm. Four 6 mm diameter mounting holes have 112.5 mm horizontal and 42 mm vertical centre spacing. Allow extra clearance for cable gland projection and cable routing. Integration requires a matched load cell, DC power supply and host. Verify the actual terminal markings, supply polarity and sensor wiring before connection. Confirm the exact model, channel count, operating power range, input range and supplied items before ordering; equipment shown in a system diagram must not be assumed to be included.

尺寸、孔位与安装

主体宽100、高69、深48.5 mm是同一外壳的三个方向,不是三种尺寸版本。131 mm为含安装耳总宽;112.5 mm为孔中心横距。电缆接头伸出长度、含接头总高度、线缆弯曲空间、孔位公差、安装螺钉及紧固扭矩均未提供,不补写。

接线与电路板可见结构

S3的PLC/工控机一侧显示电源+、电源−、RS485A、RS485B和屏蔽线;传感器侧显示激励+、激励−、信号+、信号−、屏蔽。按图视角,左侧五位依次为屏蔽线、RS485B、RS485A、电源−、电源+;右侧五位依次为激励+、激励−、信号+、信号−、屏蔽。端子位置并非可脱离实物标识使用的引脚编号。

图上四线传感器标有EXC+、EXC−、SIG+、SIG−。六线图另外出现SEN+、SEN−,但变送器上未显示独立SEN端子。[uncertain] 按图线条,SEN+、SEN−似与相同极性的EXC端共接;图线重叠且无文字说明,需要厂家确认。不能因此宣传独立六线远端补偿或不受线长影响。客户页只说明存在两种线制示意,提示确认SEN接法。

图片可见复位按钮、地址拨码、电源/收发指示灯及120Ω电阻开关。电阻启用条件、开关方向、复位行为、地址拨码表及寄存器定义未提供。底部图对比独立支路走线和经模块再接其他设备的走线;不能据示意图推导电气隔离、抗干扰等级、线色极性或完整接地规则。接线操作建议为断电核对端子标识、正负极、A/B、EXC/SIG,并取得完整确认图后操作;这不增加厂家性能规格。

English specifications

尺寸与安装 / Dimensions and mounting

中文EnglishValue
主体宽度,不含安装耳Main body width, excluding mounting flanges100 mm
总宽,含安装耳Overall width, including mounting flanges131 mm
外壳高度,不含电缆接头伸出Housing height, excluding cable gland projection69 mm
外壳深度Housing depth48.5 mm
安装孔Mounting holes4 × Ø6 mm
安装孔中心横距Horizontal hole centre spacing112.5 mm
安装孔中心纵距Vertical hole centre spacing42 mm

技术参数

参数名称单位参数值
电源V DC7 – 28
功耗W< 1
工作电流mA取决于传感器负载,最大 500
工作温度°C-40 ~ 85
湿度% RH0–95(无冷凝)
防护等级-IP65
支持传感器-惠斯通电桥式应变称重传感器
激励电压V DC5 ± 3%
传感器驱动能力Ω最多 8 × 350
输入信号范围mV0 – ± 30
分辨率-1/500,000
采样率Hz10, 40, 640, 1280
通讯接口-RS485、Modbus RTU
波特率-2400 – 500000
从机地址-DIP 0–15;软件 1–255;广播 254
模块重量g≈ 250

技术文档

产品说明书1 份 · 点击选择
1 / 1 · 1 份
软件与工具1 份 · 点击选择
1 / 1 · 1 份
观看视频
CONFIGURATION OPTIONS

推荐组合方案

组合方案_2眼__07_组合方案__cfb165a427f8.jpg组合方案_20mm__07_组合方案__b10714b8284e.jpg组合方案_30 25 10 S__07_组合方案__384d7a38fe72.jpg组合方案_41 扭矩__07_组合方案__80f6e7dcff22.jpg组合方案_130足立__07_组合方案__3ab0fde58d3a.jpg组合方案_130足立模块__07_组合方案__3de229db8d0d.jpg